Our consultants are here to help you. Close collaboration and constant communication are vital in safety engineering. We team up with you to provide comprehensive field services. At HIMA, we understand that no two industrial plants are the same. Create your very own service package to meet your unique needs. You receive a security report with recommendations for optimization.

Functional Safety Review identifies if appropriate procedures and systems are in place in accordance with the functional safety life cycle requirements Read more. HIMA solutions can be safely integrated with all leading distributed control systems. Our dedicated DCS team of experts offers consulting and support. With over 50 years of experience in safety automation systems, our experts can solve any technical issues you may have. Keep up-to-date: experts from HIMA offer comprehensive seminars on the safety of industrial plants.

Do you require a certificatation concerning the operation of safety controllers? Take part in the HIMA training program. You will be logged out in 60 seconds. Do you want to stay signed in? This also reduces the effort required for certification. This means faster validation and commissioning. All applications are not equally critical. HIMax enables you to determine for yourself how redundantly your safety system should be structured.

At maximum development, each input, each output, and each processor are present four times. Even if three systems should fail, your plant is still safeguarded. HIMax systems can be structured with physical separation. This means you are continuously protected against common cause failures. If, for example, due to a fire in a control room, individual components of the safety system fail, the second system in a different room can seamlessly continue operation.

The result: maximum fault tolerance and availability. HIMax is modular. If you decide to change your processes or facilities, you can also flexibly adapt your safety system. And because each module is self-contained, including the power supply, installation is executed in the minimal possible time. New hardware is automatically detected - so there is no need for rewiring, recoding or additional planning.

HIMax constantly tests itself. You can read off the status directly on the device at any time via the LEDs. You can tell at a glance whether redundancy is available, whether the system bus is working faultlessly, if an internal error has been detected in the system, or if an error is present in the field.

Short-circuits or line-breaks are detected immediately and can be rectified much more quickly. Diagnostic data can be directly transmitted to your control system. All maintenance tasks are also logged. It enables you to thoroughly test application software before commissioning. You can find more information:.

Skip navigation SILworX. Multiforce Up to five users can carry out forces simultaneously on one controller. Centrally configure and program your safety controllers — and diagnose errors at the same time.

Wizards simplify the learning process. Your maintenance staff can get started quickly without having to first learn new programming languages. With numerous convenience functions, programming is executed quickly in the graphic environment.

The software helps users avoid errors. Rights management and antivirus and firewall compatibility offer additional protection. Highlights Function Blocks Certificates.

Alternatively, you can use structured text ST to program calculations or the C code function block option, with which you can use pretested C code. Control and monitor your plants, without having to first program the necessary functions yourself.

For burner applications For load control and combined control in industrial furnaces For turbines For compressors For motion monitoring. SILworX fulfills the following international standards: IEC — Support for all functions and variables in safety-related programming IEC — Guidelines for functional safety in the process industry More about international standards.

Cybersecurity Included. Upon startup, the software automatically performs a cyclic redundancy check CRC to detect errors in installation data and identify manipulation. Additional CRCs ensure that function-relevant project parts are also protected against undesired changes — a code comparison presents deviations graphically. SILworX can also log all changes, helping you always maintain an overview and easily restore earlier project versions if needed.